13.3. Printout interval
Printout interval determines how often data on drying process is sent through
RS 232 port. Available settings: 1, 2, 3, 5, 10, 20, 30, 60, 120, 180 seconds
(setting <---> results in printing only a header and a footer respectively,
drying process start and drying process end, halfway results are not printed
line).
13.4. Determining range of data sent during drying process
YES - data limited to drying process result only (printout of a single
like).
no - printout of complete report from drying process: header, line,
footer.